Configuring SBC User Information Table through Web Interface

You can configure the User Information table for SBC users through the Web interface. The table allows you to do the following:

Manually add users (described below).
Import users from a file: From the Action drop-down list, choose Import.
When you import a file, all previously configured entries in the table are deleted and replaced with the users from the imported file.
For configuring users in a file for import, see Configuring SBC User Information Table from a Loadable File.
Export the configured users to a file (.csv file format): From the Action drop-down list, choose Export and save the file to a folder on your computer.
Register and un-register users:
To register a user: Select the user, and then from the Action drop-down list, choose Register.
To un-register a user: Select the user, and then from the Action drop-down list, choose Un-Register.

To configure the User Information table, make sure that you have enabled the feature (see Enabling the User Info Table).

To configure User Information table through the Web interface:
1. Open the User Information table (Setup menu > Signaling & Media tab > SBC folder > User Information).
2. Click New; the following dialog box appears:

3. Configure a user according to the table below.
4. Click Apply.

User Information Table Parameter Descriptions

Parameter

Description

'Index'

[SBCUserInfoTable_Index]

Defines an index number for the new table row.

Note: Each row must be configured with a unique index.

'Local User'

[SBCUserInfoTable_LocalUser]

Defines the user and is used as the Request-URI user part for the AOR in the database.

The valid value is a string of up to 60 characters. By default, no value is defined.

Note: The parameter is mandatory.

'Username'

[SBCUserInfoTable_Username]

Defines the username for registering the user when authentication is necessary.

The valid value is a string of up to 60 characters. By default, no value is defined.

'Password'

[SBCUserInfoTable_Password]

Defines the password for registering the user when authentication is necessary.

The valid value is a string of up to 20 characters.

Note: The password cannot be configured with wide characters.

'IP Group'

[SBCUserInfoTable_IPGroupName]

Assigns an IP Group to the user. The IP Group is used as the Request-URI source host part for the AOR in the database.

To configure IP Groups, see Configuring IP Groups.

Note:

The parameter is mandatory.
You must assign the user with a User-type IP Group.

'Status'

[SBCUserInfoTable_Status]

(Read-only field) Displays the status of the user:

"Registered": Valid configuration and the user is registered.
"Not Registered": Valid configuration but the user has not been registered.
"N/A": Invalid configuration as the user has not been assigned an IP Group.
"NA": Invalid configuration as the user has been assigned a Server-type IP Group instead of a User-type IP Group.